Digital Electronic Spray Control Desc - WAGNER PROSPRAY 3.29 Owner's Manual

Hide thumbs Also See for PROSPRAY 3.29:
Table of Contents

Advertisement

PS 3.29 / 3.31
4.7
DIGITAL ELECTRONIC SPRAY CONTROL
DESC
The Digital Electronic Spray Control (DESC)
i
increases the functionality of the sprayer. It is
installed directly below the pressure control
knob on the control panel. It consists of a display
and four function keys.
various menu screens that allow the user to
customize and monitor sprayer operation using
the function keys.
SET MPa
Display
ACTUAL MPa
Function
Keys
The pressure control knob overrides the Digital
i
Electronic
Spray
Anytime the pressure control knob is turned, the
sprayer pressure will change accordingly.
FUNCTION KEYS
The function keys are numbered 1–4. Each key is labeled with
an additional function as well.
Pressing the #1 key scrolls through the
#1/Menu Key
available menu screens or performs a
function described on the active menu
screen.
Pressing the #2 key performs a function
#2/p Key
described on the active menu screen or
increases a value.
Pressing the #3 key performs a function
#3/q Key
described on the active menu screen or
decrease a value.
Pressing the #4 key selects the active
#4/Select Key
menu screen or performs a function
described on the active menu screen.
MENU SCREENS
Several menu screens are available for the user to customize
and monitor sprayer operation. They include Main Screen,
Volume Pumped, Job Volume, Unit Serial #, Timers, Job Timers,
Service Time, Security Code, Prime, and Rapid Clean.
The display shows
23.0
22.5
Control
(DESC)
settings.
MAIN SCREEN
The Main Screen is the default screen
for the control system at sprayer
startup. Pressing the #2 key switches
between PSI, BAR and MPa units of
measure. Press the #1 key to scroll through the remaining
menu screens.
For sprayers equipped with an nine-language
i
Digital Electronic Spray Control (DESC):
Pressing the #2 key at the Main Screen switches
between PSI, Bar and MPa units of measure.
Pressing the #3 key at the Main Screen changes
the language of the text on the display. There
are a total of nine languages available. Each time
the #1 key is pressed, a di昀昀erent language will
appear. The languages, in order of appearance,
are: English, Spanish, Dutch, Danish, Swedish,
German, French, Italian, and Portuguese.
VOLUME PUMPED SCREEN
The Volume Pumped screen shows
the total number of gallons or liters
sprayed by the sprayer.
To select the Volume Pumped
screen, press the #4 key.
JOB VOLUME SCREEN
The Job Volume screen allows the
user to reset a liter counter to track
usage on speci昀椀c jobs.
To select the Job Volume screen,
press the #4 key.
UNIT SERIAL # SCREEN
The Unit Serial # screen shows the
sprayers serial number.
To select the Unit Serial # screen,
press the #4 key.
starting OperatiOn
SET MPa
23.0
ACTUAL MPa
22.5
VOLUME PUMPED
MENU-1
SELECT-4
GALLONS
X
MENU-1
LITRES-2
LITRES
X
MENU-1
GALLONS-2
JOB VOLUME
MENU-1
SELECT-4
GALLONS
XXXX
MENU-1
RESET-3
UNIT SERIAL #
MENU-1
SELECT-4
SER # XXXXXXXXXX
MENU-1
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prospray 3.310558005055803705580060558038

Table of Contents