Digital Electronic Spray Control (Desc) - WAGNER ProSpray 3.39 Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for ProSpray 3.39:
Table of Contents

Advertisement

4.7

Digital Electronic Spray Control (DESC)

The Digital Electronic Spray Control (DESC) increases the functionality
of the sprayer. It is installed directly below the pressure control
knob on the control panel. It consists of a display and four function
keys. The display shows various menu screens that allow the user to
customize and monitor sprayer operation using the function keys.
SET MPa
Display
ACTUAL MPa
Function
Keys
The pressure control knob overrides the Digital
i
Electronic Spray Control (DESC) settings. Anytime the
pressure control knob is turned, the sprayer pressure
will change accordingly.
Function Keys
The function keys are numbered 1–4. Each key is labeled with an
additional function as well.
#1/Menu Key
Pressing the #1 key scrolls through the available menu screens or
performs a function described on the active menu screen.
#2/g Key
Pressing the #2 key performs a function described on the active menu
screen or increases a value.
#3/h Key
Pressing the #3 key performs a function described on the active menu
screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs a
function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize and
monitor sprayer operation. They include Main Screen, Volume
Pumped, Job Volume, Unit Serial #, Timers, Job Timers, Service Time,
Security Code, Prime, and Rapid Clean.
Main Screen
The Main Screen is the default screen for
the control system at sprayer startup.
Pressing the #2 key switches between PSI, Bar and MPa units of
measure. Press the #1 key to scroll through the remaining menu
screens.
i
For sprayers equipped with an nine-language Digital
Electronic Spray Control (DESC):
Pressing the #2 key at the Main Screen switches
between PSI, Bar and MPa units of measure.
ProSpray 3.39
GB
23.0
22.5
SET MPa
23.0
ACTUAL MPa
22.5
11
Current Select Screen
The Current Select screen allows you to
toggle between operating in 15 Amp or 20
Amp mode.
To select the Current Select screen, press the #4 key. Pressing the
#2 or #3 allows you to choose the desired mode. When the screen
displays the desired mode, press the #1 key to save and return to the
remaining menu screens.
Volume Pumped Screen
The Volume Pumped screen shows the
total number of gallons or liters sprayed by
the sprayer.
To select the Volume Pumped screen, press
the #4 key.
job Volume Screen
The Job Volume screen allows the user
to reset a liter counter to track usage on
specific jobs.
To select the Job Volume screen, press the
#4 key.
unit Serial # Screen
The Unit Serial # screen shows the sprayers
serial number.
To select the Unit Serial # screen, press the
#4 key.
Timers Screen
The Timers screen shows the total time the
sprayer has been turned on as well as the
total time the sprayer has been running (pumping).
To select the Timers screen, press the #4
key.
job Timers Screen
The Job Timers screen allows the user to
reset the "ON TIME" and "RUN TIME" to
track time on specific jobs.
To select the Job Timers screen, press the
#4 key. "JOB ON" screen will appear. Press
#3 to reset. Press #1 to continue to "JOB
RUN" screen. Press #3 to reset. Press #1
to scroll through the remaining menu
screens.
Service Time Screen
The Service Time screen allows the user to
set a service time interval (in hours). Below
the set time, the screens shows the current amount of hours on the
sprayer since the last activation of the service timer. To select the
Service Timer screen, press the #4 key.
To set the service time, press the #2 (up)
and/or the #3 (down) keys to the desired
time (run hours will increase/decrease in increments of 25 for each
time you press a key).
When the service time interval is set and met by the run hours, the
display will show a "Service Required" screen. The pump will remain
functional. To return to the Main Screen, press the #1 key. Doing so
will reset the "Service @" and "Run Hours" displayed on the Service
Screen back to 0.
Starting operation
CURRENT SELECT
MENU-1
SELECT-4
VOLUME PUMPED
MENU-1
SELECT-4
GALLONS
X
MENU-1
LITRES-2
LITRES
X
MENU-1
GALLONS-2
JOB VOLUME
MENU-1
SELECT-4
GALLONS
XXXX
MENU-1
RESET-3
UNIT SERIAL #
MENU-1
SELECT-4
SER # XXXXXXXXXX
MENU-1
TIMERS
MENU-1
SELECT-4
ON TIME
XXXX
RUN TIME
XXXX
JOB TIMERS
MENU-1
SELECT-4
JOB ON
X
MENU-1
RESET-3
JOB RUN
X
MENU-1
RESET-3
SERVICE TIME
MENU-1
SELECT-4
SERVICE @
XX
RUN HOURS
XX

Advertisement

Table of Contents
loading