THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
DANGER
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
WARNING
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER
INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE
TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
The data plate is located behind the screened door under the control
NOTICE
panel. The oven voltage, wattage, serial number, wire size, and clearance
specifications are on the data plate. This information should be carefully
read and understood before proceeding with the installation.
The installation of any components such as a vent hood, grease
NOTICE
extractors, fire extinguisher systems, must conform to their applicable
National, State and locally recognized installation standards.
ELECTRICAL CONNECTION
Install the legs to the oven.
Electrical service connections can be made through an 11/4 knockout in the bottom of the oven
below the electrical controls.
Remove the cover attached to the oven circuit breakers for access.
Power connections can be made to the wires extending from the bottom of the circuit breakers.
Each wire has three numbers approximately two feet apart.
For Service connection and Phasing refer to the wiring diagram located at the back of this
manual.
Pull the wires out the front. Observe the three sets of numbers. Cut the wires as indicated:
1. For bottom deck or single deck installations cut each wire 3-inches below numbers 1; 2; 3;
4.
2. For middle deck or double deck installations cut each wire 3-inches below numbers 5; 6; 7;
8.
3. For top deck or triple deck installations cut each wire 3-inches below numbers 9; 10; 11; 12.
Place second oven on top of bottom oven and route the four wires through the bushing of the
lower oven. They should now be in proximity of the wires from the bottom deck.
A single power connection can now be made at the bottom deck. Through the hinged door of
the bottom oven, group and tape together the wires as indicated in the service connection chart
located in the wiring diagram at the end of this manual.
UL File E8138