I n s t a l l i n g t h e E F X 6 0 0 l a m p
Warning!
Wear safety glasses and gloves and allow the Mania EFX600
to cool for at least 10 minutes before replacing the lamp.
1. Disconnect the fixture from power and allow it to cool for at least 10
minutes.
2. Loosen the screw
holding the lamp
cover (see illustration
on right) and open the
cover. The cover is
attached to the
housing with a safety
strap.
3. Loosen the four small
screws (see illustration on right)
holding the lampholder and pull
the lampholder gently out of the
fixture. Note which edge faces
outwards, as the lampholder must
be reinstalled in the same
position.
4. If replacing an old lamp, remove it
from its ceramic socket.
5. Hold the new lamp by its base (do
not touch any other part of the
lamp). Push the lamp pins
squarely into the socket.
6. If you touched the bulb, the
reflector or any optical
components, clean them with a
clean, soft, lint-free cloth wetted
with isopropyl alcohol and dry with
a clean, soft, lint-free cloth or
compressed air.
7. Replace the lampholder in the housing, making sure that the edge with
the semicircular cutout in its center faces out towards the edge of the
and reinstall the four screws. Close the lamp cover, checking that no
wires are trapped, and replace the lamp cover screw.
8. Reapply power.
Service and maintenance
Lamp
adjustment
This edge
faces out
Lamp
adjustment
Lamp
adjustment
25