1.4 INSTALLATION ENVIRONMENT

Contact local building authority before installation to determine if a
permit and/or inspection is required.
When locating your appliance, consider the building structure to ensure
the vent will not interfere with any ceiling joists, roof rafters, wall
studs, water pipes or electrical wiring. It may be easier to relocate the
appliance than to rework the building structure.
The layout of your house and the location of the pellet stove will
determine how effective it is at heating the intended area.
Pellet stoves use mainly air circulation to disperse their heat, therefore
a central location works best.
Consider the following things when selecting a location:
- use of an existing chimney
- location of vent termination
- aesthetic considerations
- interference with house framing, plumbing and wiring
- floor protection
- room traffic patterns
- proximity to combustibles
- location of air for combustion
- electrical outlet
- pellet fuel storage

1.5 CAPACITY LOAD OF THE FLOOR

Check the load-bearing capacity of the floor, referring to the weight of
the product given in the paragraph "TECHNICAL DATA".
If the floor does not have a suitable load-bearing capacity, adequate
countermeasures must be taken.
6
The room where the appliance is to be installed must comply with the
following requirements:
a
They must not be used as a garage, store for combustible
material or for activities with a risk of fire.
a
Locating the stove in a room with an explosive athmosphere
is prohibited.
a
If the flooring is made of wood, provide a floor protection
surface in compliance with current national standards.
a
They must not be in a vacuum in relation to the outside
environment due to the effect of contrary draught caused
by the presence in the room where the firebox is installed of
another appliance or an extractor device.
d
The stove or firebox must not be used simultaneously with
collective type ventilation ducts with or without extractor fan,
other devices or other appliances such as: forced ventilation
systems or other heating systems using ventilation to
change the air. Such systems could cause a vacuum in the
environment of installation even if installed in adjoining or
communicating rooms.
H07032120 / DT2002308 – 00