National Instruments NI-488.2 User Manual page 103

National instruments user manual ni-488.2
Hide thumbs Also See for NI-488.2:
Table of Contents

Advertisement

ESRQ (16)
Solutions
ETAB (20)
Solutions
© National Instruments Corporation
ESRQ can only be returned by a device-level
the mask. ESRQ indicates that a wait for RQS is not possible because the
GPIB SRQ line is stuck on. This situation can be caused by the following
events:
Usually, a device unknown to the software is asserting SRQ. Because
the software does not know of this device, it can never serial poll the
device and unassert SRQ.
A GPIB bus tester or similar equipment might be forcing the SRQ line
to be asserted.
A cable problem might exist involving the SRQ line.
Although the occurrence of ESRQ warns you of a definite GPIB problem,
it does not affect GPIB operations, except that you cannot depend on the
RQS bit while the condition lasts.
ibsta
Check to see if other devices not used by your application are asserting
SRQ. Disconnect them from the GPIB if necessary.
ETAB occurs only during the
indicates that there was some problem with a table used by these functions:
In the case of
FindLstn
have enough room to hold all the addresses of the Listeners found.
In the case of
FindRQS
given table were requesting service.
In the case of
FindLstn
, check to see if other devices not used by your application are
FindRQS
asserting SRQ. Disconnect them from the GPIB if necessary.
Appendix C
and
FindLstn
, ETAB means that the given table did not
, ETAB means that none of the devices in the
, increase the size of result arrays. In the case of
C-9
Error Codes and Solutions
call with RQS set in
ibwait
functions. ETAB
FindRQS
NI-488.2 User Manual for Windows