National Instruments NI-488.2 User Manual page 101

National instruments user manual ni-488.2
Hide thumbs Also See for NI-488.2:
Table of Contents

Advertisement

ECAP (11)
Solutions
EFSO (12)
Solutions
© National Instruments Corporation
If the returned
ibwait
application are resynchronized.
The I/O is canceled; the driver and application are
ibstop
resynchronized.
The I/O is canceled and the interface is reset; the driver
ibonl
and application are resynchronized.
ECAP results when your GPIB interface lacks the ability to carry out an
operation or when a particular capability has been disabled in the software
and a call is made that requires the capability.
Check the validity of the call, or make sure your GPIB interface and the
driver both have the needed capability.
EFSO results when an
performing a file operation. Specifically, this error indicates that the
function is unable to open, create, seek, write, or close the file being
accessed. The specific operating system error code for this condition
is contained in
ibcntl
Possible solutions for this error are as follows:
Make sure the filename, path, and drive that you specified are correct.
Make sure that the access mode of the file is correct.
Make sure there is enough room on the disk to hold the file.
Appendix C
contains CMPL, the driver and
ibsta
or
call encounters a problem
ibrdf
ibwrtf
.
C-7
Error Codes and Solutions
NI-488.2 User Manual for Windows

Advertisement

Table of Contents
loading