Single-Ended Connections For Floating Signal Sources (Rse Configuration); Figure 2-9. Single-Ended Input Connections For Nonreferenced Or Floating Signals - National Instruments DAQ AT-MIO-16X User Manual

Multifunction i/o board for the pc at/eisa
Table of Contents

Advertisement

Nonreferenced
or Floating
V
Signal
s
Source
I/O Connector
© National Instruments Corporation
and 15 are on pins 17 and 18, which are the farthest analog inputs
from AI GND. The sensitivities to noise of the other channels in the
middle are between those of Channels 0 and 15 and vary according to
their distance from AI GND. If AI SENSE is used as a reference instead
of AI GND, the sensitivity to noise still varies among the channels,
but in this case according to their distance from AI SENSE, pin 19
(so Channel 15 is the least sensitive and Channel 0 is the most
sensitive).
Single-Ended Connections for Floating Signal
Sources (RSE Configuration)
Figure 2-9 shows how to connect a floating signal source to an
AT-MIO-16X board configured for single-ended input. The
AT-MIO-16X analog input circuitry must be configured for RSE input
to make these types of connections. Configuration instructions are
included in Chapter 4, Register Map and Descriptions.
+
-
Input Multiplexer
AI SENSE
AI GND
A T-MIO-16X Board in the RSE Input Configuration

Figure 2-9. Single-Ended Input Connections for Nonreferenced or Floating Signals

ACH<0..15>
2-27
Chapter 2
Configuration and Installation
PGIA
+
Gain
+
Measured
-
V
m
V oltage
-
AT-MIO-16X User Manual

Advertisement