Sharp AR-M450 Service Manual page 95

Hide thumbs Also See for AR-M450:
Table of Contents

Advertisement

41-3
Purpose
Operation test, check
Function (Content)
Used to check the operation of the document
size sensor and the related circuit.
(The output level of the document size sensor
can be monitored on the LCD display.)
Section
Other
Item
Operation
Operation/Procedure The OC document sensor detection level is
displayed. (Real time display)
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200
PD2[128]: 200
PD3[128]: 50
PD4[128]:
PD5[128]: 51
PD6[128]:
PD7[128]: 52
<List of display values>
OCSW
Original cover state
Open : Normal display
Close : Highlighted
PD1 ~ 7
PD sensor detection level
Figures in [ ] indicate the adjustment threshold values
(41-2 adjustment value).
52
50
AR-M350 SIMULATIONS 10-34
Main code 43
43-1
Purpose
Setup
Function (Content)
Used to set the fusing temperature in each
operation mode.
Section
Fusing, paper exit
Item
Operation
Operation/Procedure The fusing control temperature is set.
The current set value is highlighted on the right
of each item. Select an item (1 - 6), and enter a
set value with 10 digit key pad. Press START key
to store the value.
SIMULATION 43-1
FUSER TEMPERATURE SET. SELECT 1 - 6, AND PRESS START.
1. INSIDE NORMAL
190
5. INSIDE MPT
2. OUTSIDE NORMAL
190
6. OUTSIDE MPT
3. INSIDE PREHEAT
130
4. OUTSIDE PREHEAT
130
Press [START] key.
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
<List of display values>
1
Heater inside/Normal
2
Heater outside/Normal
3
Heater inside/Pre-heat
4
Heater outside/Pre-heat
5
Heater inside/Manual paper feed
used
6
Heater outside/Manual paper feed
used
180
180
1
Press [CUSTOM SETTING] key.
190
(Enter the value with 10-key)
Default
Set range
190
165~210
190
165~210
150
100~160
150
100~160
190
165~210
190
165~210