Sharp AR-M450 Service Manual page 87

Hide thumbs Also See for AR-M450:
Table of Contents

Advertisement

24-5
Purpose
Data clear
Function (Content)
Used to reset the developer counter.
(The developer counter of the DV unit installed is
reset.)
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Counter
Operation/Procedure Select with 10 digit key pad and press START
key.
The procedure below is executed and the display
returns to the original state.
1: Counter is cleared 2: Not cleared
SIMULATION 24-5
DEVELOPER COUNTER DATA CLEAR. PRESS START.
1. DV CARTRIDGE
Press [START] key.
SIMULATION 24-5
DV CARTRIDGE COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
<List of set values>
1
Developer cartridge counter
24-6
Purpose
Data clear
Function (Content)
Used to reset the copy counter.
Section
Item
Counter
Operation/Procedure Select with 10 digit key pad and press START
key.
The procedure below is executed and the display
returns to the original state.
1: Counter is cleared 2: Not cleared
SIMULATION 24-6
COPY COUNTER DATA CLEAR. PRESS START.
1. COPY
Press [START] key.
SIMULATION 24-6
COPY COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
<List of set values>
1
Copy effective paper counter
1
Press [CUSTOM SETTING] key
or [START] key.
1
1
Press [CUSTOM SETTING] key
or [START] key.
1
AR-M350 SIMULATIONS 10-26
24-7
Purpose
Data clear
Function (Content)
Used to clear the OPC drum counter and the
toner cartridge counter.
(Perform when the OPC drum is replaced.)
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Counter
Operation/Procedure Select with 10 digit key pad and press START
key.
The procedure below is executed and the display
returns to the original state.
1: Counter is cleared 2: Not cleared
SIMULATION 24-7
DRUM/TONER COUNTER DATA CLEAR. SELECT‚AND PRESS START.
1. DRUM CARTRIDGE
2. TONER CARTRIDGE
Press [START] key.
SIMULATION 24-7
DRUM CARTRIDGE COUNTER DATA CLEAR.
ARE YOU SURE ?
1. YES
2. NO
<List of set values>
1
Drum cartridge counter
2
Toner cartridge counter
24-9
Purpose
Data clear
Function (Content)
Used to clear the printer print counter.
(After completion of maintenance, this counter
must be cleared.)
Section
Printer
Item
Counter
Operation/Procedure Select with 10 digit key pad and press START
key.
The procedure below is executed and the display
returns to the original state.
1: Counter is cleared 2: Not cleared
SIMULATION 24-9
PRINTER/OTHERS COUNTER DATA CLEAR. SELECT‚1-2, AND
PRESS START.
1. PRINTER
2. OTHERS
Press [START] key.
SIMULATION 24-9
PRINTER COUNTER DATA CLEAR.
ARE YOU SURE ?
1. YES
2. NO
<List of set values>
1
Printer counter
2
Other effective paper counter
1
Press [CUSTOM SETTING] key
or [START] key.
1
1
Press [CUSTOM SETTING] key
or [START] key.
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m350

Table of Contents