Head-End HDTV Converter to IP
GSS
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg
DVB-C/T
HDMC 1000 SPTS
Phone:
+49 (0) 911 / 703 8877
Fax:
+49 (0) 911 / 703 9210
E-mail:
info@gss.de
Internet:
http://www.gss.de/en
SPTS
CLASS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDMC 1000 SPTS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GSS HDMC 1000 SPTS

  • Page 1 Head-End HDTV Converter to IP DVB-C/T SPTS HDMC 1000 SPTS CLASS Phone: +49 (0) 911 / 703 8877 Fax: +49 (0) 911 / 703 9210 Grundig SAT Systems GmbH E-mail: info@gss.de Beuthener Strasse 43 Internet: http://www.gss.de/en D-90471 Nuremberg...
  • Page 2: Table Of Contents

    Output parameter ................20 Switching the IP address off or on ..........21 Transmission protocol ..............21 Port number ................21 Quantity of data packets ............22 Forward error correction ............22 Transmission channel ..............22 Output IP addresses ..............23 Allocating services ..............24 - 2 - HDMC 1000 SPTS...
  • Page 3 DVB service information ............26 Output data rate ................27 Factory reset ................27 Saving settings ................28 Operation with a CA module ............28 PID monitoring ...............28 Configuring the CA module .............29 Descrambling services .............30 6 Final procedures ..................32 - 3 - HDMC 1000 SPTS...
  • Page 4: Safety Regulations And Notes

    The current software versions can be found at "www.gss.de/en". Take action to prevent static discharge when working on the device! Electronic devices should never be disposed of in the household rubbish. In accordance with directive 2002/96/EC of the European Parliament and the European Council from January 27, 2003 which addresses old electronic and electrical devices, such devices must be disposed of at a designated collection facility. At the end of its service life, please take your device to one of these public collection facilities for proper disposal. - 4 - HDMC 1000 SPTS...
  • Page 5: General Information

    2.1 P aC k i n g C o n t e n t s 1 Cassette HDMC 1000 SPTS 2 HF cables 1 Brief assembly instructions 2.2 m...
  • Page 6: Description

    227.40.50.94 : 1234 "Tuner B" Service 6 227.40.50.95 : 1234 Service 7 227.40.50.96 : 1234 ASI input Service 8 227.40.50.97 : 1234 Service 9 227.40.50.98 : 1234 ASI output Service 16 227.40.50.105 : 1234 - 6 - HDMC 1000 SPTS...
  • Page 7 You can find the current operating software for the control unit and the cassette, the software "BE-Flash" and the current assembly instructions on the website "www.gss.de/en". The cassette is intended for use in the STANDARD LINE head-end stations. - 7 - HDMC 1000 SPTS...
  • Page 8: Software Query

    • Align the cassette and apply slight pressure to connect it to the connections of the board and the HF bus bar. • Fasten the cassette with the screws 0° ACHTUNG! MESSAUSGANG Vor dem Cassettenwechsel unbedingt Netzstecker ziehen! CAUTION! Before changing cassettes remove mains plug! - 8 - HDMC 1000 SPTS...
  • Page 9: Emc Regulations

    19" cabinet. Tighten the nuts on the cable terminals until the teeth on the lock washer have pen- etrated the exterior coating and a good connection is made between the housing and cable terminals. - 9 - HDMC 1000 SPTS...
  • Page 10: Cassette Overview

    —> In order to avoid restrictions of the network data rate (and therefore possible disturbances) we recommend to operate other applications like e.g. Internet, VOIP telephony etc. in separated networks. —> Exclusively use "Layer 3 switches", which support the IGMP protocol. • Connect the ASI input and the ASI output to the peripheral ASI devices. - 10 - HDMC 1000 SPTS...
  • Page 11: Retrofitting A Ca Module

    CA module facing the top side of the cassette. • Push the CA module without canting into the guide rails of the CA slot and contact it to the common interface. - 11 - HDMC 1000 SPTS...
  • Page 12: The Control Panel At A Glance

    The key pad on the head-end station is used to scroll through the menus: scrolls forward through the menus. select parameters in the menus. set values, initiate actions. selects sub-menus. scrolls backward through the menus. saves all entries. - 12 - HDMC 1000 SPTS...
  • Page 13: Programming

    / off PID Check Bx 1A Menu <= => Edit ◀ ▶ Bx 1A TV 04/09 X / 0 - 13 - ..HDMC 1000 SPTS X – entschlüsseln descrambling 0 – nicht entschlüsseln no descrambling...
  • Page 14 EIT TDT TXT SDT (ON / off) copy Bx 4 DATARATE 72.956 Mbps page 13 Werkeinstellwerte Bx 4A FACTORY Bx 4A FACTORY aufrufen ▶ invoke factory defaults Defaults => STORE => M speichern / store - 14 - HDMC 1000 SPTS...
  • Page 15: Programming Procedure

    • Select the cassette you want to program (e.g. Box 4) by repeatedly pressing the button if necessary. —> The display shows e.g. the menu "Box 4 T/C-SPTS": "Box 4" stands for slot 4 "T/C-SPTS" type of cassette "V 30" software version of the cassette - 15 - HDMC 1000 SPTS...
  • Page 16: Ethernet Parameters

    If a server is not connected, " 0*" appears in the corresponding menu. The star " * " in the display means that the data is provided by a DHCP server. Bx 4 IP-ADDR 192.168. 0.128 - 16 - HDMC 1000 SPTS...
  • Page 17: Address Range

    IP address displayed to be set and use to set the IP address wished. • Press the button. —> The "UDP port" – "UDP-PORT" menu is activated. - 17 - HDMC 1000 SPTS...
  • Page 18: Udp Port

    —> No submenus are available for selection ASI. Herein you can only check whether an input signal is present or not. • Press the button. —> The "Kind of modulation / Symbol rate" – INPUT" submenu is activated. - 18 - HDMC 1000 SPTS...
  • Page 19: Kind Of Modulation / Symbol Rate

    INPUT 746.00 • Use the buttons to position the cursor under the digit to be set for the input channel / input frequency then use to set the desired input channel / input frequency. - 19 - HDMC 1000 SPTS...
  • Page 20: Output Parameter

    —> In the second line of the display the service is indicated allocated to the IP output (e.g. "arte"). • Press the button. —> The "Switching the IP address off or on, Transmission protocol, Port number" – "MODE / PORT" submenu is activated. - 20 - HDMC 1000 SPTS...
  • Page 21: Switching The Ip Address Off Or On

    " 1234". • Use the buttons to position the cursor under the digit of the port number displayed to be set. • Using the buttons set the port number wished. - 21 - HDMC 1000 SPTS...
  • Page 22: Quantity Of Data Packets

    "off" . —> In position "off" the forward error correction (FEC) is switched off. • Using the buttons set the value of the FEC wished ("off, 10/9" … "20/19"). IP 1 PKTS / FEC 10/09 AnnexB - 22 - HDMC 1000 SPTS...
  • Page 23: Output Ip Addresses

    Allocating IP addresses to services manually: • Press the buttons to position the cursor under the digit of the IP ad- dress to be set. • Using the buttons set the IP address wished. - 23 - HDMC 1000 SPTS...
  • Page 24: Allocating Services

    TV or test receiver is darkened. " * " The star means that the TV or radio station selected is scrambled. To enable the stations, the CA module and the appropriate smart card of the station pro- vider are required. - 24 - HDMC 1000 SPTS...
  • Page 25: Sound Options Of The Service

    IP 1 AUDIO • Press to select the desired sound option (e.g. "all", "deu" – German, "2ch" etc.). • Press the button. —> The "DVB service information" – "OPTIONS" submenu is activated. - 25 - HDMC 1000 SPTS...
  • Page 26: Output Data Rate

    —> The "Output parameter" – "IP-OUT …" menu is activated (page 20). • Repeat the settings until all services wished are allocated to an IP address. • Press the button. —> The "Output data rate" – "DATARATE" main menu is activated. - 26 - HDMC 1000 SPTS...
  • Page 27: Factory Reset

    —> The factory defaults are saved. The display shows "STORE" —> Back to "Selecting the cassette" (page 15). —> By pressing the button, you will be returned to the menu item "Ethernet parameters" without saving the factory defaults (page 16). - 27 - HDMC 1000 SPTS...
  • Page 28: Saving Settings

    PID monitoring can be switched off. Bx 4A PID Check • Use the buttons to switch "off" or "on" the PID monitoring. • Press the button. —> The "Configuring the CA module" – "CA" submenu is activated. - 28 - HDMC 1000 SPTS...
  • Page 29: Configuring The Ca Module

    —> You will be returned to the "Configuring the CA module" – "CA" submenu item. —> By pressing the button you can cancel the settings in the menu of the CA module and are returned to the "Configuring the CA module" – "CA" menu. - 29 - HDMC 1000 SPTS...
  • Page 30: Descrambling Services

    ("X") or not to decrypt them ("0"). Save changes and activate the filter: • Press the button. —> The filter is activated. The display shows the "Configuring the CA module" – "CA" menu. Bx 4A Menu <= => Edit - 30 - HDMC 1000 SPTS...
  • Page 31 • Press the button. —> The "Input data stream" – "INPUT" menu is activated (page 19). - 31 - HDMC 1000 SPTS...
  • Page 32: Final Procedures

    Pro C e d u res After installing the head-end station, upgrading accessories or installing cas- settes it is necessary to tighten all cable connections, cable terminals and cover screws in order to maintain compliance with current EMC regulations securely. • Securely tighten the cable bolted connections using an appropriate open- ended spanner. • Mount the front cover (see assembly instructions of the head-end station). - 32 - HDMC 1000 SPTS...
  • Page 33 Declaration of CE conformity - 33 - HDMC 1000 SPTS...
  • Page 34 Service: Phone: +49 (0) 911 / 703 2221 • Fax: +49 (0) 911 / 703 2326 • Email: service@gss.de Grundig SAT Systems GmbH • Beuthener Straße 43 • D-90471 Nürnberg • Germany Alterations reserved. Technical data E. & O.E. © by GSS GmbH...