Detection range of the human sensor is as follows.
Vertical angle 90° (Side view)
7 m
90°
6.1. Installation dimensions
Wall hook
bracket
127 mm or over
1.8 m
1.5 m or over
or over
Remote
controller
6.2. Indoor unit piping direction
The piping can be connected in the 6 directions indicated in the following.
When the piping is connected to direction (2) , (3) , (4) or (5) , cut along the piping groove
on the side of the front cover with a hacksaw.
(2) Right
outlet
(1) Rear outlet
(3) Bottom outlet
6.3. Cutting the hole in the wall for the connecting piping
(1) Cut a 65 mm diameter hole in the wall at the position shown in the following.
(2) Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3) Always align the center of the wall hole. If misaligned, water leakage will occur.
(4) Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with
vinyl tape, and stick the pipe through the hole.
(5) For left piping and right piping, cut the hole a little lower so that drain water will flow
freely.
Wall hook bracket
65 mm dia. hole
Fasten with
vinyl tape
Wall pipe*
(Inside)
Wall cap*
Always use the wall pipe. If the wall pipe is not used, the cable that is connected between
the indoor unit and the outdoor unit may touch metal, and cause an electric discharge.
6.4. Installing the wall hook bracket
• Remove the wall hook bracket from the indoor unit. (Remove screw).
ASTG18KMCA_中型標準モデルLM系_R32_0724m.indd
Horizontal angle 100° (Top view)
7 m
50°
50°
84 mm
or over
133 mm or over
(Wall cap)
Remote controller holder
Tapping screw (small)
(Rear)
(5) Left
outlet
(6) Left rear
outlet
(4) Left bottom outlet
Center mark
65 mm dia. hole
5 to 10 mm low
(Outside)
*Field supplied
Wall
WARNING
5
(1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically.
If the wall hook bracket is titled, water will drip to the floor.
(2) Install the wall hook bracket so that it is strong enough to support the weight of the unit.
• Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the
outer edge of the bracket.
• Check that there is no rattle at the wall hook bracket.
Wall hook bracket
Tapping screw
CAUTION
Install the wall-hook bracket both horizontally and vertically aligned.
Misaligned installation may cause water leakage.
6.5. Forming the drain hose and pipe
[Rear piping, Right piping, Bottom piping]
• Install the indoor unit piping in the direction of the wall hole and bind the drain hose
and pipe together with vinyl tape.
• Install the piping so that the drain hose is at the bottom.
• Wrap the pipes of the indoor unit that are visible from the outside with decorative tape.
[For Left rear piping, Left piping]
Interchange the drain cap and the drain hose.
CAUTION
• I nsert drain hose and drain cap securely. Drain should slope down to avoid water leakage.
• W hen inserting the drain hose, no other material than water should be applied.
Application of other material than water will cause deterioration of the hose, and may
cause water leakage.
• A fter you remove a drain hose, be sure to attach the drain cap.
• W hen you secure the piping and drain hose with tape, arrange the drain hose so that
it is at the bottom of the piping.
• F or drain hose piping in low temperature environment, you need to apply freeze
protection to prevent a frozen drain hose.
After cooling operation is performed in low temperature environment, (when outdoor
temperature under 0 °C,) water in the drain hose could be frozen. Frozen drain water
will block the water flow in the hose, and may cause water leakage at the indoor unit.
Installing the Drain cap
Use a hexagonal wrench 4 mm at opposite side to
insert the drain cap, till the drain cap contacts the tip
of the drain cock.
Right piping
Indoor unit drain hose (bottom)
Bottom piping
Indoor unit
drain hose
No gap
Drain
cock
Hexagonal
Drain cap
wrench
Bind with vinyl tape
Refrigerant pipes (top)
Rear piping
For left outlet piping,
cut off the piping
outlet cutting groove
with a hacksaw.
Drain cap
Remove the drain cap by pull-
ing at the projection at the end
of the cap with pliers, etc.
En-5