8. COMPRESSOR CONTROL

1. OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the table10.
(Table10 : Compressor Operation Frequency Range)
AOTG18KMCA
AOTG22KMCA
AOTG24KMCA
2. OPEARTION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the Fig.9.
(Fig.9 : Compressor Control at Start-up)
Frequency
Frequency
Frequency
Frequency
Frequency
(Frequency)
AOTG18/ 22/ 24KMCA
(Time)
AOTG18/ 22/ 24KMCA
Cooling
Min
Max
10rps
99rps
Time
Time
Frequency
Frequency
35rps
53rps
Time
Time
80sec
160sec
01-09
Heating
Min
Max
12rps
120rps
Time
Time
Frequency
Frequency
66rps
Time
Time
300sec
440sec
Dry
Min
Max
16rps
27rps
Time
Frequency
82rps
106rps
Time
500sec