On Line Operating Mode

Figure 57 - On Line Mode Selection
This operating mode causes the reader to be connected to an external Presence Sensor
using EXT TRIG+ and EXT TRIG- inputs.
During the active phase of the presence sensor, the DX6400/DX6500 reader tries to acquire
and correctly decode the code.
In case the decoding phase is successful, the barcode characters are transmitted on the
serial interface. Otherwise, a no read message is sent.

Automatic Operating Mode

Figure 58 - Automatic Mode Selection
This operating mode does not require the connection to an external Presence Sensor.
When working in this mode the reader is continuously scanning, while the reading phase is
activated each time a barcode enters the reader reading zone. The reader stops reading
after an N number of scans without a code.
Barcode characters are transmitted on the serial interface. In case of a failed reading phase
no message is sent to the host computer.