2

Outputs

Three general purpose outputs are available.
Pin
Name
8
OUT 1+
22
OUT 1-
11
OUT 2+
12
OUT 2-
16
OUT 3A
17
OUT 3B
The function of the three outputs OUT1, OUT2 and OUT3 can be defined by the user.
Refer to Genius™ Help On-Line for further details.
By default, OUT1 is associated with COMPLETE READ event, which activates when the code
has been read correctly. In case the reader has been programmed to read several codes
within the same reading phase, the event activates when all codes have been read.
OUT2 is associated with NO READ event, which activates when no code has been read.
OUT3 is associated with NONE, which means that the output is always in line state.
The OUT1 and OUT2 electrical features are given below:
Collector-emitter voltage
Collector current
Saturation voltage (VCE)
Maximum power dissipation
The limit requested by the maximum power dissipation is more important than that of the
maximum collector current: if one of these outputs is continuously driven, the maximum
current must not be more than 40 mA although 130 mA may be reached in pulse conditions.
OUT3 has different electrical features, since it is a bi-directional solid state relay with a
built-in current limit protection. If this output is continuously driven, the maximum current
must be not more than 200 mA although more than 300 mA may be reached in pulse
conditions for an ambient temperature of 25°C. At the maximum ambient temperature of
50°C the maximum respective current is 160 mA continuous and 240 mA pulse.
16
Function
Configurable digital output 1 – positive pin
Configurable digital output 1 – negative pin
Configurable digital output 2 – positive pin
Configurable digital output 2 – negative pin
Configurable digital output 3 – polarity insensitive
Configurable digital output 3 – polarity insensitive
30 V Max.
130 mA Max.
1 V at 10 mA Max.
90 mW at 50°C (Ambient temperature).
DX6X00
+
-
Figure 23 – Output 1 and Output 2 Interface
USER INTERFACE
Vext 30 Vdc max
DX6400/DX6500

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx6500