The following image shows a system consisting of five readers where the Master reader
receives external signals (trigger, serial to host, etc.) and together with Slave 1 and Slave 2
is powered by the C-BOX 100, while Slave 3 and Slave 4 are connected to the power supply
through the PWR-120 and the 610X cable. This is due to the fact the C-BOX 100 can supply
a maximum of 3 readers. This means that the CAB611X cable connects two different groups:
Master, Slave 1, Slave 2 AND Slave 3, Slave 4. It does not propagate power but only
network and synchronization signals.
The CAB-6310 power cable has two AWG 20 wires (VS + GND) and connects PWR-120 to
Slave 3.
CAB610X
CAB600X
BTK6000
C-BOX 100
Master
Slave 1
*P.S.
CAB610X
Local Host
Slave 2
Slave 4
BTK6000
Slave 3
CAB610X
CAB611X
PWR-120
CAB-6310
*
P.S. (Presence Sensor) connected to External Trigger input.
Figure 47 – Single P.S. with more than 2 Readers and Single Power Unit