READING FEATURES
4
Figure 67 – Setting PackTrack™ Parameters
The PackTrack parameters PS Offset and Direction are set in the PackTrack DX area. See
the scanner Help On-Line for details.
For DX6400, the Flash™ Command area allows setting a fixed scanner focus position or the
dynamic D-Flash automatic focus.
The Run Test button allows testing the calibration results and efficiency.
By pressing the Calibrate DX button, a warning appears advising that the PackTrack
calibration will be overwritten.
Yes
Figure 68 – Performing the PackTrack™ Calibration
If you continue, a dialog box is opened which allows calibration. After placing the code at the
desired position (Position 1), enter its X, Y and Z coordinates within the corresponding edit
boxes. Then, press the Calibrate button to start the calibration.
Repeat the same procedure for Position 2 and Position 3.
Before closing the dialog box, press the "Validate Calibration" button to validate the
calibration settings.