7
Barcode Image Input Window
1
Laser Beam Output Window
2
3
Power On LED
4
Good Read LED
For further details on product installation, see the
complete Installation Manual.
DS2200 can be configured through the WinHost
Windows-based software program available on the
installation CD-ROM.
For configuration it is necessary to create a cable
connecting the scanner to the PC as indicated in
the "How To Build A Simple Interface Test Cable"
section of this guide.
POWER SUPPLY
- This product is intended to be installed by
Qualified Personnel only.
- DS2200 All Models:
This accessory device is intended to be supplied by
a UL Listed Power Unit with «Class 2» or LPS
power source which supplies power directly to the
scanner via the 25-pin connector.
Laser Barcode Reader
Quick Reference Guide
6
5
4
3
2
1
8
Figure A
Ext Trig LED
5
TX Data LED
6
Mounting Holes
7
Laser Warning and
8
Device Class Label
DS2200
The scanner is classified as a Class 2 laser product
according to EN 60825-1 regulations and as a Class
II laser product according to CDRH regulations.
For installation, use and maintenance it is not
necessary to open the device.
There is a safety device which allows the laser to be
switched on only if the motor is rotating above the
threshold for its correct scanning speed.
The laser beam can be switched off through a
software command (see also the WinHost Help On
Line).
Warning and device class labels
The laser diode used in this device is classified as a
class 3B laser product according to EN 60825-1
regulations and as a Class IIIb laser product
according to CDRH regulations. As it is not possible
to apply a classification label on the laser diode
used in this device, the following label is
reproduced below.
Any violation of the optic parts in particular can
cause radiation up to the maximum level of the
laser diode (7 mW at 630 to 680 nm).
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1 mW
EMITTED W AVELENGTH 630~680 nm
TO EN 60825-1:2001
CAUTION-CLASS 3B LASER LIGHT
WHEN OPEN AVOID EXPOSURE TO BEAM
This product conforms to the applicable
requirements of 21CFR1040 at the date of
manufacture.
DATALOGIC S.p.A. Via Candini, 2
40012 Calderara di Reno - Bologna - Italy
LASER LIGHT
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
MAX. OUTPUT RADIATION 7 mW
EMITTED WAVE LENGTH 630~680 nm
TO EN 60825-1 (2001)
Laser diode class label

Advertisement

loading

Summary of Contents for Datalogic DS2200

  • Page 1 Good Read LED reproduced below. Device Class Label For further details on product installation, see the complete Installation Manual. DS2200 can be configured through the WinHost LASER LIGHT AVOID EXPOSURE TO BEAM Windows-based software program available on the CLASS 3B LASER PRODUCT installation CD-ROM.
  • Page 2 DS2200 QUICK GUIDE Available Models: DS2200 - X X X X Optical Resolution Communication Interface Optic Version Reading Window Position 1 = Standard resolution 1 = RS232+ RS485 0 = Linear 0 = Direct 2 = High resolution 1 = Raster The following tables display each version’s reading performance.
  • Page 3 DS2200 QUICK GUIDE Electrical Connections: DS2200 is equipped with a cable terminated by a 25-pin female D-sub connector for connection with the power supply and input/output signals. Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
  • Page 4: External Trigger

    DS2200 QUICK GUIDE Input/Output Connections: Input Output DS2200 EXTERNAL TRIGGER DS2200 USER INTERFACE Vext 50 Vdc max, 50 mA max. 9/13 VS = 5 Vdc + 5V 8/11 OUT 1+ / OUT 2+ EXT TRIG- I/O REF 10/12/22 Signal Ground...
  • Page 5 The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 25-pin D-sub male 9-pin D-sub female TXAUX RXAUX SGND DS2200 EXT TRIG- Power Supply VS (5 Vdc) Power GND Trigger Test Cable for DS2200...
  • Page 6 DS2200 QUICK GUIDE Reading Diagrams: DS2200-1XXX (Standard Resolution) (in) 80 100 120 140 160 180 200 220 240 260 (mm) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0°...
  • Page 7 Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS2200-XXXX Laser Scanner e tutti i suoi modelli and all its models et tous ses modèles und seine modelle y todos sus modelos...