INSTALLATION
The general purpose input IN1, in the Standard Application Program, can be used to
store the code verifier (see "Store Verifier Hw" in the WinHost Help On Line).
An anti-disturbance hardware filter is implemented on the External Trigger input
(about 1 millisecond delay).
An additional 15 ms (typical) delay can be implemented through a dedicated software
parameter (refer to WinHost Help On Line).
2.3.5

Outputs

Two general purpose outputs are available. These outputs can only be connected as
open collector configurations. The following pins are present on the 25-pin connector
of the scanner:
Pin
8
11
12, 22
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No
Read, Right, Wrong, or a combination). Refer to the WinHost Help On Line.
DS1100
+ 5 V
47 K
18
IN1 -
GND
12/22
Figure 12 - IN1 - Input Command
Name
OUT1+
OUT2+
GND
User Interface
Ground
Function
output 1 +
output 2 +
I/O reference
2