Main Switch; Condenser - Yamaha SRX700D Service Manual

Hide thumbs Also See for SRX700D:
Table of Contents

Advertisement

IGNITION SYSTEM

MAIN SWITCH

1. Disconnect:
Main switch coupler
2. Connect:
Pocket tester
3. Check:
Main switch continuity
Faulty → Replace.
SDN8180
Switch position
Switch
position Y/B Y/R
OFF
ON1
ON2
START

CONDENSER

1. Disconnect:
Condenser 1
SDN8190
2. Connect:
Condenser
(to the LCR meter)
3. Measure:
Condenser capacity
Out of specification → Replace.
Condenser capacity:
8-7
ELEC
Continuity
OFF
ON
Color code
Br
R
R/W
Continuity
4,700 µF at 20˚C (68˚F)
+
Yes
No
B
B/W

Advertisement