CONVERSION KIT INSTRUCTIONS
CONVERT THE GAS CONTROL VALVE:
Follow stepper motor pressure regulator instruction sheet included with conversion kit to
convert gas valve. ( L P o r N A T m a r k e d o n s t e p p e r m o t o r p r e s s u r e
regulator).
COMPLETE THE CONVERSION:
1.
Adjust burner tube venturis to correct setting by loosening screws, adjusting caps
and retightening screws.
CORRECT SETTINGS: NAT. : Both venturis - 1/16" (2mm) open
2.
Re-install front burner into fireplace, pull bracket forward until orifice is properly
seated inside burner venturi; tighten bracket nut.
3.
Install back (top) burner. Burner venturi extends through center opening on front
(bottom) burner and sits down over back burner orifice. Ensure pilot assembly sits
above burner. Align holes in both burners and secure with screws previously
removed.
4.
Re-install logs.
Turn on gas and electrical supplies. Check for leaks at all connections soapy water,
5.
whether field or factory made.
6.
Test inlet pressure. Visually check pilot flame. Flame should envelope top of flame
sensor and extend onto burner far enough for proper ignition. To Adjust pilot: Turn
pilot adjustment screw clockwise to decrease or counter-clockwise to increase pilot
flame.
7.
Turn fireplace off.
8.
Affix gas type sticker to label.
9.
Re-install glass frame and screen front assemblies.
10. Verify proper ignition and operation of fireplace.
11. Complete and affix 'Gas Conversion' label to outer wrap close to gas valve.
MINIMUM INLET GAS PRESSURE
MAXIMUM INLET GAS PRESSURE
MANIFOLD PRESSURE (HI)
MANIFOLD PRESSURE (LO)
L.P. : Both venturis - 5/8" (16mm) open
NATURAL GAS
5" WC (1.25 kPa) (7" WC (1.74 kPa) recommended)
10.5" WC (2.62 kPa)
3.5" WC (.87 kPa)
1.6" WC (.40 kPa)
PROPER BURNER / PILOT ORIENTATION
(Your pilot may look slightly different than one shown)
Figure 17a
Figure 17b
LP GAS
11" WC (2.74 kPa) (recommended)
13" WC (3.24 kPa)
10" WC (2.49 kPa)
6.4" WC (1.59 kPa)
17
GAS CONVERSION LABEL
(included with conversion kit)