ELECTRICAL WARNING / INFORMATION:
Electrical wiring must be installed by a licensed electrician.
Do NOT wire 120V to wall switch.
Uninterrupted or continuous power is required at all times in IPI systems EXCEPT when using battery back-up.
Incorrect wiring will override IPI safety lockout and may cause an explosion.
Disconnect 120V before servicing.
A duplex receptacle and box cover are supplied in fireplace components packet to be used when hardwiring to electrical box located under
firebox on right side of fireplace. Ensure duplex box cover is installed with flange to top.
THIS SYSTEM GOES THROUGH A CALIBRATION MODE WHEN SWITCHING FROM ON TO THERMO TO OFF
ATTENTION
MODES, CREATING A HUMMING SOUND WHICH IS A NORMAL PART OF OPERATION.
CONTINUOUS PILOT
The IPI gas control system has the option of a continuous (standing) pilot feature. This allows you to change from a spark-to-pilot system to
a standing pilot system during cold weather conditions. By having the pilot on continuously, the firebox will remain warm and a draft is
established in the vent, allowing the main burner to turn on with less air-flow disruption.
When continuous pilot mode is activated and fireplace is turned ON, the pilot will spark and light. When fireplace is turned OFF, the
pilot will remain lit when main burner has been turned OFF.
This pilot feature can be activated or de-activated by the hand held remote control transmitter. Instructions on following page.
OPERATION USING BATTERY POWER
This fireplace has an optional battery operation if electrical power is lost. Position battery pack with four "AA" size batteries installed
between valve and front of fireplace. This is the coolest location under firebox, ensuring longer battery life.
NOTE
When operating fireplace in this capacity, the only function available is flame modulation.
LEARN BUTTON ACCESS PROCEDURE
Prior to installation: Access thr ough hole on r ight side of inser t.
After installation:
1.
Remove screen front and glass frame assembly to expose components on right side wall of insert.
2.
Move battery pack away from front of main control module.
3.
Using a needle nose pliers, remove pilot connection tabs from main control module. Main control module can now be rotated forward
to access LEARN button.
4.
Reattach pilot connection tabs (top-black, bottom-red), reattach battery pack and install glass frame assembly and screen front.
PRE-INSTALLATION
LEARN BUTTON ACCESS HOLE
Figure 23a
IPI INFORMATION
(FOR VERY COLD CONDITIONS)
LEARN BUTTON
SLIDE TO REMOTE POSITION