REMOTE CONTROL INFORMATION cont.
CONTINUOUS PILOT FEATURE:
Activation of this optional feature is accomplished by pressing the PILOT
button once. The continuous pilot icon will appear on the LCD screen.
Pressing
PILOT
button
This feature can also be activated via CONTINUOUS PILOT switch on Main
Control Module.
CHILDPROOF FEATURE:
Activation of this optional feature is accomplished by pushing SET & UP
buttons simultaneously for 5 seconds. The childproof icon will appear on the
screen. When a transmitter button is pressed the icon will flash on screen, but
no signal will be transmitted. Pressing and holding these same two buttons
again
for
more
than
5
This feature controls only manual functions of the hand held remote,
automatic
functions
(thermostat
MANUAL MODE:
This
remote
can
be
Press MODE button for manual ON. The flame icon will appear on the LCD
screen. Press MODE button again to put the control into THERMO mode.
Pressing MODE again will turn fireplace OFF.
The MODE button operates in a series that will cycle from
NOTE
ON to THERMO to OFF.
FAN MODE:
This remote will operate the fan, allowing for (6) different speed levels. When
the FAN button is pressed, FAN level setting will flash on the LCD screen.
Press UP or DOWN buttons to select desired fan speed level. If no
adjustment is made within 7 seconds, the control will exit function setting
mode and LCD display will return to normal view.
Delayed ON/OFF - The fan will not turn on until fireplace
has been burning for 5 minutes and will not turn off for 12
minutes after fireplace has been turned off.
NOTE
EXCEPTION: If fireplace is turned back on during 12 minute
off-delay time frame, the fan will remain on.
This applies to MANUAL and THERMO modes.
LIGHTING MODE: (
This remote will operate the lights, allowing for (6) different light levels.
When LIGHT button is pressed, LIGHT level setting will flash on the LCD
screen. Press UP or DOWN buttons to select desired light level. If no
adjustment is made within 7 seconds, the control will exit function setting
mode and LCD display will return to normal view.
There is a 3 second delay before light level setting is achieved.
NOTE
Light operations are completely independent from flame and
fan operations.
again
will
de-activate
seconds
will
de-activate
mode)
will
not
manually
or
thermostatically
not operational in all models)
this
feature.
Figure 25a
this
function.
be
effected.
Figure 25b
operated.
Figure 25c
Figure 25d
Figure 25e
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents