REMOTE CONTROL INFORMATION cont.
FLAME MODE:
This remote will operate the flame, allowing for (6) different flame height
levels. When MAIN FLAME button is pressed, FLAME level setting will
flash on the LCD screen. Press UP or DOWN buttons to select desired flame
level. If no adjustment is made within 7 seconds, the control will exit function
setting mode and LCD display will return to normal view.
The fireplace will initially light at the highest level.
After 5 seconds the flame will adjust to last chosen
NOTE
level before fireplace was turned OFF.
This applies to MANUAL and THERMO modes.
THERMO (THERMOSTAT) MODE:
This remote feature allows you to thermostatically control the fireplace when hand held remote is set to
THERMO mode.
Set Temperature Range: 45˚F (7˚C) to 90˚F (32˚C).
Set remote to THERMO mode by pressing MODE button. The smaller SET window of numbers appears
on the LCD screen. The first SET number will read 45˚F. Press UP button to desired set room temperature.
Within 5 seconds fireplace will operate to that Set Temperature. The FLAME, ON and THERMO icons
will appear on the LCD screen. By pressing UP or DOWN buttons a new set temperature may be attained.
SET
Temperature
will
but
is
implemented
in
The flame height can adjust up to (6) different height levels according to amount of heat
NOTE
required. This range however is dictated by the Flame Level setting (see previous page).
When desired temperature is met, the fireplace will shut off until more heat is required.
To exit THERMO mode press the MODE button. This also shuts fireplace OFF.
When in THERMO mode the fireplace will not turn on until room temperature falls below
IMPORTANT
SET TEMPERATURE.
SYSTEM OPERATION WITHOUT HAND HELD REMOTE:
This system is designed to operate with the hand held remote or a thermostat, but in the unlikely event that it is required to be operated
without the hand held remote or a thermostat, follow this simple procedure.
Slide REMOTE/OFF switch on main control module to OFF. The fireplace can now be lit and shut off by use of the ON/OFF rocker switch.
NOTE
When operating fireplace in this capacity, the only function available is burner operation on HI.
Figure 26c
only
appear
when
THERMOSTAT
all
MODES
with
the
REMOTE / OFF
Figure 26a
MODE
is
exception
of
MANUAL
26
activated,
MODE.
Figure 26b