Openport Platform Standby; Wobbling; No Activity Power Off; Osd Language - Panasonic TH-55AF1U Operating Instrctions

Hide thumbs Also See for TH-55AF1U:
Table of Contents

Advertisement

OpenPort PLATFORM standby

This switches the operation status of the OpenPort
PLATFORM system in standby mode.
For TH-55AF1W, TH-49AF1W and TH-42AF1W
[Off]:
When the power is turned off with remote control,
etc.
Shuts down the OpenPort PLATFORM system.
When it is in standby condition (Power Indicator:
Red)
It is possible to startup with remote control or RS-232C,
but it is not possible to startup with timer setting, wired
LAN or wireless LAN.
[On] (Factory default):
When the power is turned off with remote control,
etc.
Does not shut down the OpenPort PLATFORM system.
When it is in standby condition (Power Indicator:
Orange)
It is possible to startup with timer setting, wired LAN
and wireless LAN.
For TH-55AF1U, TH-49AF1U and TH-42AF1U
[Off] (Factory default):
When the power is turned off with remote control, etc.
Shuts down the OpenPort PLATFORM system.
When it is in standby condition (Power Indicator:
Red)
It is possible to startup with remote control or RS-232C,
but it is not possible to startup with timer setting, wired
LAN or wireless LAN.
[On]:
When the power is turned off with RS-232C control
or LAN control
Does not shut down the OpenPort PLATFORM system.
When the power is turned off with something other
than RS-232C control or LAN control
Shuts down the OpenPort PLATFORM system once,
and then restarts the system. During that time (approx.
60 seconds), the power on processing is not accepted.
When it is in standby condition (Power Indicator:
Orange)
It is possible to startup with timer setting, wired LAN
and wireless LAN.

Wobbling

Automatically shifts the display image (therefore
unnoticeable to the eye) to prevent image retention of
sharper contour of image.
Setting this to [On] moves the screen position at certain
intervals and displays the images.
Note
If [Multi display setting] is set to [On], this function
does not operate. (see page 84)
When this function is operating, part of the screen
may appear to be missing.

No activity power off

When this function is set to [Enable], the power is turned
off (standby) automatically when there is no operation of
the Display for 4 hours.
Starting from 3 minutes before the turn off, the
remaining time will be displayed.
Press any key to abort.
No activity power off
When the power is turned off due to this function, a
message [Last turn off due to 'No activity power off'.]
is displayed next time the power is turned on.
Note
While the screensaver is running, this function is
disabled.
This function is not activated with OpenPort
PLATFORM input.

OSD language

Select your preferred language.
Selectable languages
English(UK)
Deutsch
Français
Italiano
Español
ENGLISH(US)
: Chinese
中文
: Japanese
日本語
Русский
: Russian
Note
It is also possible to set language in [Language &
input] in OpenPort PLATFORM. (see page 58)
The display may be greyed out and setting cannot
be made in some conditions, such as when the
OpenPort PLATFORM system is starting up.
3 min
English
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-49af1uTh-49af1wTh-42af1wTh-42af1uTh-55af1w

Table of Contents