5.21
Claim: d3 after changing ELIN
Warning!
Before changing any part check all connections.
5.21.1 Symptons
In TouchControl nothing is displayed, or does nothing.
ELIN , which supplies TouchControl , is changed and then the
mistake d3 appears
Fan is checked and it is correct, it is changed and continuous
failure d3.
5.21.2 Cause
Connections probably are not good connected on the fan connector
(XFAN.). They are in another connector
5.21.3 Solution
If the failure d3 continues, change again the ELIN, which is connected
to the fan and send an eFSB.
206_58300000141095_ara_en_k.doc – 04.10.a