For the previous project IH4-I:
Two levels of residual heat indication
60ºC 65ºC 80ºC 85ºC
60ºC 65ºC 80ºC 85ºC
60ºC 65ºC 80ºC 85ºC
„h „ is shown when the temp. Of the NTC of the inductor is higher
than 65 ºC and lower than 80 ºC. and disappears when the temp is
lower than 60 ºC.
"H" is shown when the temp. of the NTC of the inductor is higher
than 85 ºC and disappears when the temp is lower than 80ºC.
206_58300000141095_ara_en_k.doc – 04.10.a
For the new project IH5-I:
Two levels of residual heat indication
Tª NTC
Tª NTC
Inductor
Inductor
„h „ is shown when the temp. of the NTC of the inductor is higher
than 65 ºC and lower than 90 ºC. and it disappears when the temp is
lower than 60 ºC.
"H" is shown when the temp. of the NTC of the inductor is higher
than 95 ºC and disappears when the temp. is lower than 90ºC.
60ºC 65ºC 90ºC 95ºC
60ºC 65ºC 90ºC 95ºC
60ºC 65ºC 90ºC 95ºC
Tª NTC
Tª NTC
Inductor
Inductor
Seite 94 von 113