3.12.1.1 Connection´s colours in englisch
In order to make the connections easier, the relay comes with colours
printed on module in englisch.
206_58300000141095_ara_en_k.doc – 04.10.a
3.12.1.2 Polarity for the oval inductors
If the inductor´s connections are not correct, the polarity from the
current that goes into the inductor can change and turn in the opposite
direction
It can be observed if we put a bräter cookware above the
combisurface and we can see how are the bubbles that appear.
3.12.1.3 New error for this relay module: e9
This new error show us that there is a stickied relay in the new
module. Swith off and swith on again the hob
Steps to check:
Possible bad connection in control cable.
Possible bad connection in power cables
Stickied relay=> change relay module