Samsung GX-20 Service Manual page 74

Hide thumbs Also See for GX-20:
Table of Contents

Advertisement

. ADJUSTMENT
2. Calibration
F or a stable light source, wait for 30 mins after turning on the power of the light source prior to
calibration.
A djust the brightness and the color temperature using the color thermometer for photography and the
LV checker as below.
Light
LV12
LV11
C alibration is performed in the following sequence with a K10D master body.
3. Master body and photometric standard lens set-up
S et the mode dial to
S et the focus mode lever to
S et the SR lever to
I nstall the photometric standard lens for adjustments and the F8 set ring on the body.
S et the aperture stop of the photometric standard lens to
4. Calibration procedure
C onnect the AC adaptor to the camera (master body).
A ccess to the PC using the USB cable.
T urn on the camera and check that the camera is recognized by the PC.
S et the light box to
P osition the lens on the top center of the light box.
74
Brightness
LV12.00Ev ±0.50
LV11.00Ev ±0.01
M
.
M F
.
O FF
.
L V12
.
- This Document can not be used without Samsung's authorization -
Color temperature
2,856K ±30
-
F 8
.