. ADJUSTMENT
If the measurement values are displayed in green, it is normal.
If the measurement values are not displayed in green and the sizes and shapes of the graphs are
different, adjust the gradient of the AF sensor by turning the two areas with an Allen wrench as shown in
the following figure. Adjust the gradient until the green appears on the screen. (The values are better to
close to "0".).
- This Document can not be used without Samsung's authorization -