. ADJUSTMENT
5. OPS gain adjustment
IMPORTANT
C AUTION 1
T his adjustment must be performed when replacing the T100 main circuit board, the
T640 relay board or the T970 circuit board.
C AUTION 2
T his adjustment must be performed after the OPS adjustment (unit adjustment).
C AUTION 3
T he adjustment must be performed on a rigid, stable and even area without vibration.
C AUTION 4
H andle the adjustment stage carefully, as it is heavy.
Do not touch the black vibration plate.
Preparation Equipment :
S R gain adjustment program (SR_GainForCS) for the GX-20
S R gain adjustment device for the GX10 (driving stage•controller•speed meter)
S R gain adjustment chart for GX10 (identical to the GX10)
P C (Windows XP (SP2), USB port standard device)
D -XENON 50-200 mm lens
U SB cable
A C adapter (or DC code for 76830)
1. Computer set-up
✂ ✄
N etFramework2.0
T he 77010
S R_GainForCS
82
a nd
V isual C++Runtime2005
f older must be copied onto the hard disk.
- This Document can not be used without Samsung's authorization -
m ust be installed on the PC already.