WARNING:
When installing the Power Module, use a cable appropriate for the
load currents: 3-core cable rated 15 A at 90 °C (194 °F) minimum, which
conform to either IEC60227 or IEC 60245. The Gateway accepts cables of 14
AWG minimum.
WARNING:
Before installing that all of three power inputs (Terminal Block/
Power Jack/Battery Input) in power module shall be protected by the 20 A
fuses or circuit-breakers(over current protection device) in front of this
system.
WARNING:
The system is for installation in a suitable industrial enclosure
(provides electrical, mechanical and fire hazard protection).
WARNING:
The core module only can be wall mounted (without the need for
an additional enclosure)
WARNING:
Only Sealed Lead Acid (SLA) battery rated 50Ah (or less) shall be
used

Professional installation instructions

Installation personnel
This product is designed for specific applications and needs to be installed by
qualified personnel with RF and regulatory related knowledge. The general user
shall not attempt to install or change the setting.
Installation location
The product shall be installed at a location where the radiating antenna is kept 20
cm from nearby persons in its normal operation condition in order to meet
regulatory RF exposure requirements.
External antenna
Use only the antenna(s) which have been approved by the applicant. Non-approved
antenna(s) may produce unwanted spurious or excessive RF transmitting power
which may lead to a violation of FCC/IC limits and is prohibited.
Installation procedure
Please refer to user's manual for the detail.