Installation Guide
Setting
DHW priority (closed valve / normal operation)
P frost T
P heat T (heat demand)
Frost pr. T (frost protection temperature)
Ext. input (external override)
Ext. mode (external override mode)
Min. act. time (min. activation time gear motor)
Upper difference
Lower difference
Delay
Lowest temp.
Heat curve
Temp. max. (flow temp. limit, max.)
Temp. min. (flow temp. limit, min.)
Adapt. time (adaption time)
Infl. - max. (room temp. limitation, max.)
Infl. - min. (room temp. limitation, min.)
High T out X1 (return temp. limitation, high limit, X-axis)
Low limit Y1 (return temp. limitation, low limit, Y-axis)
Low T out X2 (return temp. limitation, low limit, X-axis)
High limit Y2 (return temp. limitation, high limit, Y-axis)
Infl. - max. (return temp. limitation - max. influence)
Infl. - min. (return temp. limitation - min. influence)
Adapt. time (adaptation time)
Priority (priority for return temp. limitation)
Actual (actual flow or power)
High T out X1 (flow / power limitation, high limit, X-axis)
Low limit Y1 (flow / power limitation, low limit, Y-axis)
Low T out X2 (flow / power limitation, low limit, X-axis)
High limit Y2 (flow / power limitation, high limit, Y-axis)
Adapt. time (adaptation time)
Actual filter
Input type
Units
Pulse
Auto saving (saving temp. dependent on outdoor temp.)
Boost
Ramp (reference ramping)
Optimizer (optimizing time constant)
Pre-stop (optimized stop time)
Based on (optimization based on room / outdoor temp.)
Total stop
Cut-out (limit for heating cut-out)
Motor pr. (motor protection)
42
DEN-SMT/DK
ECL Comfort 210, application A260
ID
11052
11077
11078
11093
11141
11142
11189
11147
11148
11149
11150
12178
12177
12015
12182
12183
12031
12032
12033
12034
12035
12036
12037
12085
12110
12119
12117
12118
12116
12112
12113
12109
12115
12114
12011
12012
12013
12014
12026
12020
12021
12179
12174
Page
Factory settings in circuit(s)
1
2
62
OFF
62
2 °C
62
20 °C
62
10 °C
63
OFF
63
SAVING
63
10
64
OFF
64
OFF
65
10 m
65
30 °C
66
1.0
67
45 °C
67
10 °C
68
OFF
69
-4.0
69
0.0
70
15 °C
70
40 °C
70
-15 °C
71
60 °C
71
0.0
71
0.0
71
25 s
72
OFF
73
73
15 °C
999.9
74
l/h
74
-15 °C
999.9
74
l/h
74
OFF
74
10
75
OFF
75
ml, l/h
75
10
76
-15 °C
76
OFF
77
OFF
77
OFF
78
ON
78
OUT
78
OFF
79
20 °C
80
OFF
VI.LG.F1.02