Portable Generator Familiarization & Troubleshooting Guide
Section 4 • Generator Assemblies
Removing Brush Assembly
It is best to leave the DPE wires connected to the brush
assembly during removal.
• Remove the two screws that hold the brush assembly
to the rear bearing carrier (Figure 4.4).
Figure 4.4 — Removing Brush Assembly
• Carefully work the brush assembly out of its mounting
in the rear bearing carrier.
• Disconnect the DPE wires and set brush holder aside
(Figure 4.5).
Figure 4.5 — Brush Assembly
Disconnecting Power Wires
• Disengage the locks that secure the connector housing
to the plug on the back of the control panel
(Figure 4.6).
Figure 4.6 — Power Cable Connector
• Remove the connector housing from the plug.
Electrical Measurements
NOTE:
Many of the electrical measurements that
are necessary to accurately troubleshoot the
Generac®
point. In order to help avoid needless disassembly,
please refer to the "Diagnostics and Adjustments"
section of this guide for specific details.The values for
individual tests can be found in the Briggs & Stratton
Power Products
Resistance Tables," Publication #87971 Rev 6 or
later.
95
Back Of Control Panel
wound generator are accessible at this
®
"Portable Generator Rotor/Stator