Before continuing with the disassembly process, visually
inspect for the following:
• Evidence of bearing failure.
• (Very fine metallic "dust" that generally
accumulates around the bearing carrier assembly.)
• Loose or broken connector at all wire ends and
insertion points into plug assemblies.
• Vibration damage (chafing) to any components due to
rubbing or other contact friction.
As well as a thorough visual inspection, there are a number
of electrical tests that can be performed at this point of
disassembly.
The actual measurement locations are described in the
section titled "Troubleshooting Flow Chart For Sincro®
Wound (Brushless Type) Generators," which begins on page
84.
Removing The Capacitor
• Remove the capacitor from its mounting clip and
carefully disconnect the wiring harness spade
connectors (Figure 4.51).
Figure 4.51 — Removing The Capacitor
Portable Generator Familiarization & Troubleshooting Guide
Isolation Mounts
• Remove the two nuts that secure the isolation mounts
to the cradle frame (Figure 4.52).
Figure 4.52 — Isolation Mount Hardware
Isolation
Mounts
Mounting
Nuts
• Support Sincro® generator with a wooden block as
shown in Figure 4.53.
Figure 4.53 — Supporting Sincro-Generator
Supporting
Block
110