Remove Wire Terminals From Connector Housing
There may be occasions where it is necessary to remove the
wire terminals from the connector housing.This would be
the case if stator replacement was required. Remove the
wire terminals from the connector housing as follows:
• With a small screwdriver or a sharp pick, bend the
locking tabs on the wire terminals back so they can
slide back through the connector housing
(Figure 4.7).
Figure 4.7 — Locking Tabs On Connector Housing
When done correctly, the wire terminal will slide out of the
connector housing as shown in Figure 4.8.
Figure 4.8 — Terminal Out Of Connector Housing
• Repeat this process until all the terminals are removed
from the connector housing.
Portable Generator Familiarization & Troubleshooting Guide
• When all of the terminals are free of the housing, bend
each of the locking tabs back to their original position
as shown in Figure 4.9.
Figure 4.9 — Terminal Locking Tabs
Vibration Mounts
• Remove the nuts holding the vibration mounts to the
underside of the cradle frame as shown in Figure 4.10.
Figure 4.10 — Vibration Mount Hardware