Surge Protection; Regulatory Compliance - American Dynamics ADCI625-P221 Configuration And User's Manual

Illustra 625
Table of Contents

Advertisement

Category
Connector
Design Tolerance

Surge Protection

The following applies:
Category
Power Line
IP
Audio
Alarm Input
Auxiliary Output

Regulatory Compliance

The Illustra 625 PTZ Camera meets the following regulatory requirements:
Emissions
Immunity
Safety
Environmental
Pluggable Euro-style pin 3.5 terminal block
connector
Input minimum:19 VAC RMS without dropout
Input Maximum:Voltage >35 VAC RMS may damage
equipment
Line Frequency:47-63 Hz
Allowable drop out:30 ms
TVS rated at 60V, 250A, 1.5 Joules, 8/20us impulse
Data lines isolation transformer coupled
TVS rated at 5V, 300 watts, 8/20us impulse
Gas discharge tube impulse rated at ten 8/20 us 5kA Impulses
TVS rated at 3.3V, 500 watts, 8/20us impulse
Gas discharge tube impulse rated at ten 8/20 us 5kA Impulses
Optocoupled with 500V isolation
Dry contact relay with1, 500 volt galvanic isolation
FCC: Part 15 Class A
CE: EN55022 Class A
AS/NZS CISPR 22 Class A
ICES-003/NMB-003 Class A
CE: EN50130-4
CE: EN55024
CE: EN61000-6-1
UL60950-1
IEC 60950-1
CSA 22.2 No. 60950
CE: EN60950-1
Outdoor: UL 50 (Type 4)
Outdoor: EN60529 (IP66)
RoHS
Technical Specifications
Details
Details
9
9-117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents