Summary of Contents for Quadra-Fire MT VERNON STOVE AE
Page 1
MT VERNON STOVE AE & MT VERNON INSERT AE Heat Exchanger & Exhaust Cleaning Instructions WARNING Fire Risk For trouble free use of your pellet appliance you must perform cleaning as called for in these instructions. Not doing so will result in: •...
Page 2
CAUTION PROPER SHUTDOWN PROCEDURE 1. Set the wall control thermostat to “OFF” on AUTOMATIC/ The appliance must be in complete shutdown, completely MANUAL SETTING screen and let the appliance com- cool and the exhaust blower off before performing any pletely cool. The exhaust blower must be off before you cleaning or maintenance.
Page 3
. Assemble the crevice tool from the Micro Cleaning Tools Needed: Shop Vac* and Micro Cleaning Kit*; flat head and Phillips screwdriver; 11/2 Nut-driver or wrench. Kit to attach to a Shop Vac. Figure 3. Figure 3 se the crevice tool to finish cleaning the heat 4.
Page 4
5. Removing the Combustion (Exhaust) Blower Loosen all 6 screws, but do NOT Remove a. The combustion blower is mounted in the bottom right rear of the appliance. Figure 5. b. Use an 11/2 nut driver to loosen all 6 nuts, but do not remove.