Quadra-Fire MT VERNON STOVE AE Cleaning Instructions

Heat exchanger & exhaust

Advertisement

Quick Links

MT VERNON STOVE AE & MT VERNON INSERT AE
Heat Exchanger & Exhaust Cleaning Instructions
www.quadrafire.com
WARNING
Fire Risk
For trouble free use of your pellet appliance you must perform cleaning
as called for in these instructions. Not doing so will result in:
• Poor operating performance
• Smoke spillage into the home
• Overheating of components
Not properly cleaning your appliance on a regular basis will void your
warranty.
Refer to your Owner's Manual for complete cleaning
instructions for all components.
7014-139F
R
June 27, 2008

Advertisement

loading

Summary of Contents for Quadra-Fire MT VERNON STOVE AE

  • Page 1 MT VERNON STOVE AE & MT VERNON INSERT AE Heat Exchanger & Exhaust Cleaning Instructions WARNING Fire Risk For trouble free use of your pellet appliance you must perform cleaning as called for in these instructions. Not doing so will result in: •...
  • Page 2 CAUTION PROPER SHUTDOWN PROCEDURE 1. Set the wall control thermostat to “OFF” on AUTOMATIC/ The appliance must be in complete shutdown, completely MANUAL SETTING screen and let the appliance com- cool and the exhaust blower off before performing any pletely cool. The exhaust blower must be off before you cleaning or maintenance.
  • Page 3 . Assemble the crevice tool from the Micro Cleaning Tools Needed: Shop Vac* and Micro Cleaning Kit*; flat head and Phillips screwdriver; 11/2 Nut-driver or wrench. Kit to attach to a Shop Vac. Figure 3. Figure 3 se the crevice tool to finish cleaning the heat 4.
  • Page 4 5. Removing the Combustion (Exhaust) Blower Loosen all 6 screws, but do NOT Remove a. The combustion blower is mounted in the bottom right rear of the appliance. Figure 5. b. Use an 11/2 nut driver to loosen all 6 nuts, but do not remove.

This manual is also suitable for:

Mt vernon insert ae