4.9 After stopping the engine – Putting the engine out of
operation
Preconditions
☑MTU Fluids and Lubricants Specifications (A001063/..) are available.
After stopping the engine
Item
Coolant circuit
Engine/generator/pump
control
Task
Drain engine coolant (→ Page 97) if:
• the engine room is not heated;
• the engine coolant is not maintained at a suitable temperature;
• the antifreeze concentration is insufficient for the engine-room tem-
perature;
• antifreeze concentration is 50 % and engine-room temperature is be-
low -40°C.
Switch OFF.
MS15022/03E 2014-02 | Operation | 75