3.3 6R 1600 B40S 50Hz engine data, optimized emissions
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
Application group
Intake air temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number of cylinders
Rated engine speed
Continuous power ISO 3046 (10% overload capability, design power DIN 6280,
ISO 8528)
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
Exhaust overpressure
Exhaust overpressure, max.
MODEL RELATED DATA (basic design)
Number of cylinders
Number of cylinders
Standard housing connecting flange (engine main PTO)
Flywheel interface (DISC)
COOLANT SYSTEM (HT circuit)
Number of cylinders
Coolant temperature (at engine connection: outlet to cooling system)
Coolant temperature after engine, warning
Coolant temperature after engine, shutdown
24 | Technical Data | MS15022/03E 2014-02
6R1600B
40S
3B
°C
25
mbar
1000
m
100
6
A
rpm
1500
A
kW
274
6
A
mbar
25
L
mbar
50
A
mbar
85
L
mbar
150
6
6
SAE
01
14"
6
A
°C
95
R
°C
105
L
°C
109