4.6.6. Sx-xxxx type error code

► Error Code
S1–1313
► Error message

The clock became initial time. Set a time again.

► Symptom
Saved time is invalid.
► Troubleshooting method
1) Set up the time and reboot the machine.
a) Select "Machine Setup" on touch screen.
b) Select "General Setting".
c) Select "Date and Time" and set the time.
2) If the problem persists, check the following.
a) Remove the rear cover.
b) Measure the voltage of the battery. If the battery is normal, the measured value is over 3V.
3) If the battery is normal, replace the main board.
► Error Code
S1–2411
► Error message

HDD System Failure: #S1-2411. Turn off then on. Call for service if the problem persists.

► Symptom
Hard Disk is not installed in the machine. / Hard Disk is defective.
► Troubleshooting method
1) Check if the HDD is installed correctly.
a) Remove the rear cover.
b) Check if the HDD cable is connected correctly.
2) If the problem persists, replace the HDD.
Copyright© 1995-2013 SAMSUNG. All rights reserved.