Samsung MultiXpress M537x series Service Manual page 199

Mono laser mfp
Hide thumbs Also See for MultiXpress M537x series:
Table of Contents

Advertisement

Diagnostics > Adjustment > Scan Area Adjustment > Manual Adjustment
Purpose
Operation Procedure
Copyright© 1995-2013 SAMSUNG. All rights reserved.
To correct image position and magnification of scanned images manually.
1) Choose one item from the table. There are three items to choose.
Image Position - Leading Edge (Unit : mm, Min/Max : -3.0/+3.0)
Image Position - Side Edge (Unit : mm, Min/Max : -3.0/+3.0)
Magnification - Vertical Direction (Unit : %, Scale: 0.1, Min/Max: 98.5/101.5)
2) Select one item and press the "Edit" button.
3) Change the adjustment value with arrow button.
4) Image Position (a, b) : If the current value is smaller than the specification, press "+".
Otherwise, press "-".
5) Magnification (c) : If the current value is smaller than the specification, press "-". Otherwise,
press "+".
6) Press the "OK" button to apply the new value to the system.
7) Copy the Scanner A/S Chart. Scanning must be occur from the DSDF.
8) To check the image position, compare the position of scale marks (a,b) of the chart to the
copy.
9) To check the magnification, compare the length of line "c" of the chart to the copy.
NOTE
Specification
a,b : 10, ± 1.5 mm
c: 190, ± 1.5 mm
4. Troubleshooting
4-63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multixpress m437x series

Table of Contents