General Information; Introduction; Specifications; Power Source Requirements - Pace IntelliHeat ST 30 Operation And Maintenance Manual

Power sources
Hide thumbs Also See for IntelliHeat ST 30:
Table of Contents

Advertisement

General Information

Introduction

Thank you for purchasing an IntelliHeat™ system.. This manual will provide you with the information
necessary to properly set up, operate, and maintain your system. Please read this manual thoroughly
before using the system.
The systems featured in this guide are available in either 115 VAC or 230 VAC versions. All of these
models incorporate Intelliheat™ technology. Intelliheat™ is the combination of THC (Tip Heater
Cartridge) and SensaTemp handpieces into one system. The system recognizes either handpiece
individually and automatically adjusts the menu driving controls for each handpiece. The 230 VAC
version system bears the CE Conformity Marking, which assures the user that it conforms to EMC
89/336/EEC. All models featured in this manual are lead free compatible and comply with RoHS and
WEEE directives.

Specifications

Power Source Requirements

Domestic Models
ST 30
ST 50
Operates on 97-127 VAC,
ST 65
50/60Hz, 80 Watts maximum at
ST 70
115 VAC, 60Hz
ST 75
ST 115
Shop Air Input Requirements (ST 65 Only)
Pressure-
Airflow-

Temperature Specifications (All Models)

Tip Heater Cartridge Handpiece Tip Temperature Range: 205 to 455°C (400 to 850°F) nominal.
SensaTemp Handpieces Tip Temperature Range: 37 to 482°C (100 to 900°F) nominal.
Digital Readout Resolution: ±5° (°C or °F)
Tip Temperature Stability: ±1.1°C (2°F) at Idle from Set Tip Temperature.
Temperature Accuracy: Meets or exceeds ANSI JSTD 001
VACUUM AND AIR (ST 65 ST 75 & ST 115) Measurements at front panel AUTO SNAP-VAC and
CONTROLLABLE PRESSURE Port.
Vacuum Rise Time: 150 ms average.
Vacuum: 20 in. Hg. (Nominal)
Pressure: (18 P.S.I.) (Nominal MAXIMUM setting)
Air Flow: 8 SLPM MAXIMUM

EOS/ESD Specifications (All Models)

Tip-To-Ground Resistance: Less than 2 ohms.
AC Leakage: Less than 2 Millivolts RMS from 50Hz to 100MHz.
Transient Level: Less than 500mV peak, out to 100MHz.
©2012 PACE Inc., Southern Pines North Carolina
5.48 Bar (80p.si.) recommended
45.3 SLPM (1.6SCFM) minimum
Export Models
ST 30E
ST 50E
Operates on 197-253 VAC
ST 65E
50/60Hz, 80 Watts maximum at
ST 70E
230 VAC, 50Hz
ST 75E
ST 115E
All Rights Reserved
Page 3 of 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents