Auto Restart Control; Indication Panel - Panasonic CS-VE9NKE Service Manual

Hide thumbs Also See for CS-VE9NKE:
Table of Contents

Advertisement

12.7.3
Sleep Timer
Sleep operation is performed according to the delay OFF time (0.5, 1, 2, 3, 5, 7 or 9 hr) and provide comfortable
environment by shifting set temperature.
Temperature Shift
Cooling
Set temperature (°C)
Heating
Stop condition
- Reached delay time.
- Pressed sleep button to cancel.
- Unit is OFF.

12.8 Auto Restart Control

When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
12.9

Indication Panel

LED
Color
Light ON
Light OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
Heating
A
2hr
B
*5am
* According to remote control clock
Status 1
Status 2
0
+1
0
-1
POWER
TIMER
Green
Orange
Operation ON
Timer Setting ON
Operation OFF Timer Setting OFF
Cooling, Dry
3hr
*4am
Status 3
Status 4
+2
+3
-2
-3
+8/10°C HEAT
nanoe-G
Green
Blue
+8/10°C HEAT
nanoe-G
Mode ON
ON
+8/10°C HEAT
nanoe-G
Mode OFF
OFF
42
ECONAVI
Green
ECONAVI ON
ECONAVI OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ve12nkeCu-ve9nkeCu-ve12nke

Table of Contents