12.2 Indoor Fan Motor Operation

12.2.1
CS-VE9NKE
Fan speed: Manual
Normal (with programmed air)
Powerful
Long Right/Left
Initial
Long Other than
airflow
Right/Left
When the area control
is in operation
Powerful
Fan
Long Right/Left
speed:
Airflow
Long Other than
Auto
stable /
Right/Left
unstable
When the area control
is in operation
Normal
Cool dry
Powerful/Long
Initial
When the area control
airflow
is in operation
Airflow
Powerful/Long
stable /
When the area control
unstable
is in operation
Fan speed: Manual
Normal
At the start of
Powerful /
operation
Fan
Long
Not at the start of
speed:
operation
Auto
When the area control is in
operation
Clothes drying
Fan speed: Manual
Unstable
Normal
Stable
Powerful
Long Right/Left
Initial
Long Other than
airflow
Fan
Right/Left
speed:
When the area control
Auto
is in operation
Powerful
Long Right/Left
Airflow
Long Other than
stable /
Right/Left
unstable
When the area control
is in operation
Hot Dry
Fan speed: Manual
Individual ventilation /
NANOE
Odor Cut Shift
Only for the COOL and COOL range
* Lock detection: When the rotation speed of 2550rpm and above or below 50rpm is detected for 10 consecutive seconds during the feedback
control, H19 is indicated (the TIMER indicator flashes) if normal rotation speed is not detected even after the retry is performed 7 times.
* Refer to the attached list of "Indoor Unit Fan Operation Status" for the operations of the indoor unit fan while the thermostat is OFF.
Stop
SSLo
O
Outside temperature is below 35°C or Neuro is
O
stable.
1230 (SHi) (1180 when the setting is changed from Hi to Powerful on the remote control.)
1290 (SHi) (1180 when the setting is changed from Hi to Long on the remote control.)
1250 (SHi) (1180 when the setting is changed from Hi to Long on the remote control.)
O
O
O
830  1220 (1300 when the setting is changed from Hi to Powerful on the remote
830  1400 (1300 when the setting is changed from Hi to Long on the remote control.)
830  1240 (1300 when the setting is changed from Hi to Long on the remote control.)
O
Fan speed: Auto
Indicates the changeable range using the remote control
SLo
Quiet Lo
480
540
580
MIN 590 ± 50 ~ 860 ± 50rpm
640  1030
660  1070
660  1050
(1) 640  1030
Range 2 540
Range 1 660
540  760
(1) 540  760
---
---
550
Min. rotation speed for each of the following fields
380
540
650
control.)
970  1090
970  1070
580
500
Below Lo: No shifting
Below Me and fan speed auto: 20
35
Lo-
Lo
Me-
580
660
820
Outside temperature is 35°C or higher
and Neuro is unstable.
980
660
980
---
690
790
710
650
730
890
1050
830  1100
910  1100
830  1220
950  1050
(1) 950  1050
max 730
660
820
Me
Hi
SHi
1100 ~
980
---
1180
940 ± 50rpm
890
990
---
1230
1090
1230
1240 ~
---
1300
980
1150
---
Me and above: 90