14.10 Auto Restart Control

When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.

14.11 Indication Panel

LED
POWER
Color
Light ON
Operation ON
Light OFF
Operation OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, operation mode judgment, or ON timer
sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
TIMER
White
White
Timer Setting
ON
Timer Setting
OFF
DEICE
+8/15°C HEAT
White
White
+8/15°C HEAT
Deice ON
ON
+8/15°C HEAT
Deice OFF
OFF
80
White
Wireless LAN Mode
nanoe
ON
Wireless LAN Mode
TM
nanoe
OFF
White
TM
X Mode ON
X Mode OFF