12.11.2. OFF Timer
• When the OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
Notes
1. By pressing ON/OFF operation button, the ON Timer or OFF Timer setting will not be cancelled.
2. To cancel the previous timer setting, press CANCEL button.
3. To activate the previous timer setting, press SET button.
4. If main power supply is switched off, the Timer setting will be cancelled.

12.12. Random Auto Restart Control

• If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
• It will start with previous operation mode and airflow direction.
• If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
• This Random Auto Restart Control is not available when Timer is set.
• This control can be omitted by open the circuit of JX02. (Refer printed circuit board indoor unit)

12.13. Remote Control Signal Receiving Sound

• Long beep sound will be heard when:
- Stopping the air conditioner using ON/OFF switch.
• Short beep sound will be heard for others setting.

12.14. Patrol Operation

1. Purpose
To monitor air dirtiness level by using gas sensor and activates e-ion operation whenever air is dirty.
2. Control Condition
a. Patrol operation start condition
• When the unit operation is started with "OFF/ON" button.
• When the unit stops, "Patrol" button is pressed, Patrol individual operation will start.
• During cooling only operation, "Patrol" button is pressed.
35