Auto Restart Control - Panasonic CU-Z20VKE Series Installation Instruction

Indoor/outdoor unit
Hide thumbs Also See for CU-Z20VKE Series:
Table of Contents

Advertisement

Control pattern:
Cooling mode
Setting
Temperature
Setting
Fan Speed
Selection of
OFF Timer
by
SLEEP
Heating mode
Set Temp
Sleep operation will not undergo temperature shift when it collaborate with below operation. However, it will
execute the delay timer.
Powerful mode operation
o
Quiet mode operation
o
Mild dry operation
o
Stop Condition:
When sleep operation is cancel by pressing respective button until sleep timer reaches 0.0h.
ON/OFF button is pressed.
When sleep operation ends.

14.10 Auto Restart Control

When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
Normal
-2°C
+1°C
60
minutes
minutes
Set Speed
Set Speed
Set Speed
0.5 hr
1.0 hr
2.0 hr
3.0 hr
4.0 hr
5.0 hr
6.0 hr
7.0 hr
8.0 hr
9.0 hr
SLEEP
is pressed
(ON)
N
r o
m
l a
1 Hr
Sleep Function activated
+1°C
+1°C
120
60
60
minutes
minutes
Set Speed
S
e l
e
p
T
m i
r e
A
-1°C
Max 9 Hrs
86
120
120
minutes
minutes
Set Speed
End of
Function
i t c
a v
e t
d
Unit Off