2.3 Cleaning

CAUTION
(a) When using a commercial neutral detergent, be
sure to use non-corrosive type.
(b) Be careful not to damage components.
When cleaning the compressor cover and the turbine
housing, observe the followings:
(1) Visually check the parts condition before cleaning to
note any burns or abrasions, which may not be
observable after cleaning.
(2) Soak the disassembled parts in the inflammable solvent
(e.g. Die Cleaner T-30 manufactured by Daido
Chemical Industry Corp.) to remove oil contaminants
and carbon attachments. However, do not soak the O-
ring, thrust bearing, and other bearings.
(3) Blow compressed air over the inside and outside
surfaces.
(4) Remove deposits using a plastic scraper or a bristle
brush. After removing deposits, soak the components in
a nonflammable solvent and apply compressed air
again.
2.3.1
Measuring axial clearance of cartridge
assembly
Set a dial indicator on the end of compressor wheel shaft as
shown.
Move the compressor wheel in the axial direction and
measure the clearance.
If the clearance is out of standard, replace the cartridge
assembly, with a new one.
Item
Axial clearance of cartridge assembly
Standard
0.057 to 0.103 mm
[0.0022 to 0.0041 in.]
INLET AND EXHAUST SYSTEMS
Combined use with an ultrasonic cleaning unit can
help to remove contaminants easily.
Cleaning turbocharger
Blow compressed air onto
Removing carbon deposits thoroughly
Compressor wheel
Cartridge assembly

Measuring axial clearance of cartridge assembly