Operational Parameters

Installation must comply with State and local plumbing regulations. Do not use with water that is micro
biologically unsafe or of unknown quality without adequate disinfection before or after the system.
System is intended to be installed using the cold water supply only.
Operating Temperatures:
Operating Pressure:
pH Parameters:
Iron:
TDS (Total Dissolved Solids)
Turbidity
Hardness
Hardness:
Recommended hardness not to exceed 10 grains per gallon, or 170 parts per million.
* System will operate with hardness over 10 grains but the membrane life may be shortened.
Addition of a water softener may lengthen the membrane life.
Water Pressure: The operating water pressure in your home should be tested over a 24 hour
period to attain the maximum pressure. If the incoming water pressure is above 100 psi then a
water pressure regulator is required. A booster pump is needed for incoming water pressure
under 40psi.
Copper Tube: Reverse Osmosis water should not be run through copper tube as the purity of the
water will leach copper causing an objectional taste in water and pin holes may form in the tube.
* Note: RO unit must be installed a minimum of 25 Pipe feet from water heater *
Contents of Reverse Osmosis (RO) System
1 Tank - White
1 RO Module (complete with filters)
1 Pump/ESOV Assembly
1 Transformer
1 Parts Bag
1 Faucet Bag
1 Manual
If any of the items are missing please contact Premier prior to installing.

Tools Recommended For Installation

√ 1 1/4" Diamond Tipped Hole Saw bit for faucet opening (Counter Tops/Porcelain & Stainless Sinks)
√ 1 1/4" Adjustable Wrench
√ 1/2" Open End Wrench
√ 5/8" Open End Wrench
√ Electric Drill
√ 1/8" diamond tip bit, pilot hole
√ 1/4" drain saddle hole
Maximum 100°F (37.8°C)
Maximum 100 psi (7.0 kg/cm
Maximum 11
Maximum 0.2 ppm
< 1800 ppm
< 5 NTU
Maximum 10 Grains Per Gallon *
INSTALLATION & STARTUP
√ Phillips bit for electric drill
√ Needle Nose Pliers
√ Adjustable Pliers
√ Sharp Knife
√ Phillips Screw Driver
2
)
Page 4
Minimum 40°F (4.4°C)
Minimum 40 psi (2.80 kg/cm
Minimum 2
2
)